Until V10 the limit of the amount of memory that could be used by BricsCAD was around 1.6 GB. In V11 or higher this limit has been increased to 4 GB on 64 bit systems and 3 GB on 32 bit systems. On 32 bit systems additional manual changes to the boot process are required.
On a 32 bit Windows Vista or Windows 7 system do the following:
- Click the Start button
on the left hand side of the Windows task bar.
- Type command in the Windows Start Search field, then press Enter.
The Administrator Command Prompt window opens.
3. Type bcdedit /set increaseuserva 3072 in the Administrator Command Prompt window, then press Enter.
The memory limit is increased to 3GB.
4. Close the Administrator Command Prompt window.